Sonel MPI540PV PVsolar & 3phase Tester
SKU: MPI540PVR88,661.00 Ex VAT
Sonel MPI540PV PVsolar & 3phase Tester
Much more than a multifunctional meter
- The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
- Removable microSD memory card – easy increase of memory capacity
- Li-Ion battery – longer operation of the meter
- MPI-540-PV | Measurement of photovoltaic installations according to EN 62446 standard
- MPI-540-PV | Cooperation with solar radiation and temperature meter
- MPI-540-PV | Photovoltaic installation test report with Sonel Reports PLUS software
- Three-phase power recorder – advanced power quality diagnostics
- Real time display of network parameters – immediate evaluation of the test site conditions
- Parameters measured in accordance to class S of EN 61000-4-30 standard – high accuracy of measurement
- Energy cost calculator – quick evaluation of potential savings
- Measurement of all parameters related to earthing and protection against electric shock – one device instead of several
- Quick measurement of the fault loop impedance in networks secured with RCD without triggering (up to several seconds) – time saver
- Auto measurements – the ability to perform automatic measurements in sequence – simplified measurements
- Fast path from measurements to report – time saver of your instruments.
Available: In stock
Available on back-order
Description
Sonel MPI540PV PVsolar & 3phase Tester includes:
The meter has high quality functionality. It combines the measuring capabilities
of multiple devices, while ensuring great accuracy.
The MPI-540-PV instrument can measure photovoltaic installations in accordance with the EN 62446 standard:
- continuity of protective and equipotential bondings,
- earth resistance,
- insulation resistance on the DC side,
- open circuit voltage UOC,
- short circuit current ISC,
- work currents and powers on both DC and AC side,
- inverter efficiency.
MPI-540 / MPI-540-PV can record 50/60 Hz power quality parameters in accordance to S class of EN 61000-4-30:
- voltage L1, L2, L3, – average values in the range up to 500 V,
- L1, L2, L3 currents, – average values, current measurement in the range
- up to 3 kA (depending on the current probes used),
- frequency in the range of 40 Hz – 70 Hz,
- active (P), reactive (Q) and apparent (S) power,
- power factor (PF), cosφ, tanφ,
- harmonics (up to 40th for voltage and current),
- total harmonic distortion (THD) for current and voltage,
- recording of events for current and voltage,
- energy flow – 4 quadrants.
MPI-540 / MPI-540-PV can be used for all measurements for commissioning of electrical installations in accordance with applicable regulations:
- short circuit loop impedance (also in circuits secured with RCDs),
- RCD parameters,
- insulation resistance,
- earth resistance (4 measurement methods + soil resistivity measurement),
- continuity of protective and equipotential bondings,
- light intensity measurement,
- phase sequence test,
- motor rotation direction test.